Skip to main content

DESIGN CALCULATION FOR COAL BURNING BOILER FIRE GRATE AREA


DESIGN CALCULATION FOR COAL BURNING BOILER FIRE GRATE AREA
 


Heat Required                : 200,000 Kcal/hr
Coal                                : 4500 Kcal/hr
Coal Efficiency              : 72%
Size of Coal Required     : 1.5” to 3”
Coal Burning Capacity of a Grate : 15 lb/ft2



Distillation Column 
If you need in PDF format please click or copy & paste on your address bar the following link:
https://drive.google.com/open?id=1vk96TnaMvwOjP5MGVKen-Px3JA4Y_-2E

Comments

Popular posts from this blog

CRYSTALLIZER DESIGN CALCULATION

Given Data Solute                                                                    : A Solvent                                                                  : B Concentration of Solute                         ...

Dimensions of Dished Ends for Pressure Vessels like Boiler, Reactor, Storage Tank

According to IS 4049 (Part-2): 1996 and Table 2 Dimensions for Dished and Flanged Ends (Torispherical) Inside Crown Radius is 80% of ID Inside knuckles Radius is 10% of ID and in no case less than 6% nor less than 3 x thickness of Dish.   Inside height of Dish can be calculated according to IS: 2825 – 1969 and IS 4049 (Part-2) : 1996 as follows: Now the Inside height can be calculated according to IS: 4179 – 1997 which is as follows:  When Knuckle Radius is 10% of ID           2. When Knuckle Radius is 6% of ID           Where h i = Inside height of Dish                       R i = Crown Radius of Dish                       r i = Knuckle radius of Dish ...